Podcast 782: Ventilator Management
Contributor: Aaron Lessen, MD
Educational Pearls:
- Tidal volume is the amount of breath a patient receives in a single ventilation
- Traditional tidal volume (TV) setting was 10 ml/kg but studies showed lower TV had less incidence of respiratory distress, ARDS, and overall better outcomes
- ED ventilation settings may get carried on for hours or days when a patient is admitted, making this an important part of patient care
- Recent large systematic review shows that low TV setting in the ED leads to decreased incidence of ARDS, shorter ICU and hospital length of stay, shorter duration of mechanical ventilation, and decreased mortality
- Consider an ED low tidal volume ventilation setting at around 6 ml/kg of predicted body weight
References
De Monnin K, Terian E, Yaegar LH, et al. Low Tidal Volume Ventilation for Emergency Department Patients: A Systematic Review and Meta-Analysis on Practice Patterns and Clinical Impact [published online ahead of print, 2022 Feb 7]. Crit Care Med. 2022;10.1097/CCM.0000000000005459. doi:10.1097/CCM.0000000000005459
Summarized by Kirsten Hughes, MS4 | Edited by John Spartz MS4 & Erik Verzemnieks, MD
The Emergency Medical Minute is excited to announce that we are now offering AMA PRA Category 1 credits™ via online course modules. To access these and for more information, visit our website at https://emergencymedicalminute.org/cme-courses/ and create an account.
You May Also Like

Be Calm and Relaxed with Rain and Thunder for Sleeping
ColoredJuice Podcast Studio

Métamorphose, éveille ta conscience !
Anne Ghesquière

HerbRally
Mason Hutchison

Inner Light
The Podcast Project

IN HINDZSIGHT
HINDZ

Guided Sleep Meditation & Sleep Hypnosis from Sleep Cove
Sleep Hypnosis, Meditations and Bedtime Stories

Por el Placer de Vivir con el Dr. Cesar Lozano
Uforia Podcasts

DORMIR RÁPIDO - Adormecerse con el Sonido
SLEEP QUICKLY

The Good Glow
The Good Glow Productions

The Reality Revolution Podcast
Brian Scott
Community discussion